Interface Specifications
2-2
2.1 I/O connector input signal
Signal name
Symbol
Connector
pin No.
(Note 2)
(Note 4)
Contents
Related control mode
EtherCAT
communications
Position Velocity Torque
Full-
close
command
monitor
(Note 3)
Input signal source SI-COM
5
Connect to the positive or negative
terminal of the external DC source
(12
–24 V).
Forced alarm input E-STOP
*
Generates Err 87.0 “Forced alarm
input error”.
✔
✔
✔
✔
-
-
Positive direction
over-travel
inhibition input
POT
[Axis A]
12
(SI6)
[Axis B]
2
(SI2)
Positive direction over-travel inhibit
input.
The operation with this input turned
ON is set up in Pr 5.04 "Setup of
over-travel inhibit input".
When using Positive direction
over-travel inhibit input, connect the
signal so that the input is turned ON
when the moving portion of the
machine travels in positive direction
exceeding a limit.
If used as a home position reference
trigger in a home position return, this
input signal should be SI6 for Axis A
and SI2 for Axis B, respectively.
The signal width should be 1 ms or
longer then at the time of closing,
and should be 2 ms or longer then at
the time of opening.
Please keep in mind that it cannot
guarantee this value.
✔
✔
✔
✔
-
✔
Negative direction
over-travel
inhibition input
NOT
[Axis A]
13
(SI7)
[Axis B]
3
(SI3)
Negative direction over-travel inhibit
input.
The operation with this input turned
ON is set up in Pr 5.04 "Setup of
over-travel inhibit input".
When using Negative direction
over-travel inhibit input, connect the
signal so that the input is turned ON
when the moving portion of the
machine travels in negative direction
exceeding a limit.
If used as a home position reference
trigger in a home position return, this
input signal should be SI7 for Axis A
and SI3 for Axis B, respectively.
The signal width should be 1 ms or
longer then at the time of closing,
and should be 2 ms or longer then at
the time of opening.
Please keep in mind that it cannot
guarantee this value.
✔
✔
✔
✔
-
✔
Near home input
HOME
[Axis A]
11
(SI5)
[Axis B]
1
(SI1)
When using the near home sensor
during the return to home position
operation, input the sensor signal.
If used as a home position reference
trigger in a home position return, this
input signal should be SI5 for Axis A
and SI1 for Axis B, respectively.
The signal width should be 1 ms or
longer then at the time of closing,
and should be 2 ms or longer then at
the time of opening.
Please keep in mind that it cannot
guarantee this value.
✔
✔
✔
✔
-
✔
(To be continued)
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...