11.5Protective functions
11-15
11.5.3 Warning functions
The PSM warning factors detected by the power supply module are shown below.
(1) Power supply module side
The power supply module warning (PSM warning) shown in the table below is detected.
During PSM warning, the ERR status lamp (red) on the front panel flashes.
For the PSM warning, refer to the operation manual of the setup support software PANATERM for Multi.
(2) Driver module side
The DM warning shown in the table below is detected on all axes of all driver modules connected to the
power supply module by inter-module communication.
Warning number
Warning name
Cause of warning
PSM
(Decimal)
DM
(Hexadecimal)
01
C3
PSM main power off warning
When the power supply module parameter PSM Pr.03
(Main power off warning detection time) is between 10 and
1999, the main power supply stopped instantaneously for
more than the set time.
02
A1
PSM regeneration overload warning
Regenerative load ratio exceeded 85% of protection level.
03
AD
PSM fan lock warning
The fan built in the power supply module has stopped for 1
second or longer.
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...