7.5About the protection function setting for homing return by using the Z phase
7-39
Protective function
Error No.
Protective function
Causes
Measures
Main
Sub
94
3
Home position return
error2
When Pr7.22 bit7 = 1 and Pr5.04 = 0 or 1
(Pr5.04 is ignored under pp mode), POT
or NOT has become ON while return
operation to detected Z phase position at
homing with Z phase.
The return amount to the detected Z
phase position became abnormal in Home
position return which used Z phase.
Expand the distance between Z phase
and POT or NOT.
After confirming the safety, it's made bit7
of Pr7.22 (Communication function
extended setup 1) =0(Invalid).