5.2Manual adjusting function
5-29
5.2.3 Block diagram of torque control mode
Telocity control of MINAS A6 Multi series, there are two modes.
Profile torque mode (tq)
Cyclic synchronous torque mode (cst)
Block diagram of torque control
*1 A slanting number shows (ex: 607Ah) the object number of EtherCAT.
*2 A bold letter number shows (ex:1.00) a parameter number.
*3 Polarity was omitted.
*4 When performing Frequency characteristic measurement (Torque speed [normal]) from the PANATERM for Multi, the driver switches
to torque control mode internally.
*5 Torque control under two-degrees-of-freedom control mode executes a similar control as torque control under the conventional control
mode.