5.2Manual adjusting function
5-55
5.2.14 Two-stage torque filter
In addition to usual 1st and 2nd torque filters (Pr1.04 and Pr1.09), another torque filter can be set.
High-frequency vibration component can be suppressed by the use of the 2-stage torque filter.
Applicable range
This function can’t be applied unless the following conditions are satisfied.
Conditions for operating 2-stage torque filter:
Control Mode
Can be used in all control modes.
Others
In servo-ON state
Elements, such as deviation counter clear command input inhibition and torque limit, other than control parameter are
set properly, and motor is running without any problem.
Cautions
If the setting value is increased excessively, the control may become unstable to produce vibration. Specify
proper setting value while checking the status of the device.
If Pr6.43 "2-stage torque filter attenuation term" is changed during operation, vibration may be generated.
Change the value while the motor is stopped.
Relevant parameters
Relevant parameters
Class No. Attribute
Title
Range Unit
Function
6
42
B
2-stage torque
filter time
constant
0 to
2500
0.01ms Sets 2-stage torque filter time constant.
The time constant is invalid if 0 is specified.
[When used for the secondary filter as Pr6.43
≥ 50]
The time constants that can be used are 4 to 159 (0.04 to 1.59
ms). (Equivalent to 100 to 4000 Hz in frequency)
Setting values 1 to 3 works as 4 (4000 Hz), and 159 to 2500
works as 159 (100 Hz).
6
43
B
2-stage torque
filter attenuation
term
0 to
1000
-
Sets attenuation term of 2-stage torque filter.
The filter degree of the 2-stage torque filter is changed according
to the setting value.
0 to 49:
Operates as the 1st filter.
50 to 1000: Operates as a 2nd filter and becomes a 2nd filter
w
ith ζ = 1.0 if setting value is 1000. As the setting
value is decreased, the filter becomes vibrational.
Use with a setting value 1000 basically.
How to use
Set a 2-stage torque filter if high-
frequency vibration can’t be removed only using usual 1st and 2nd
torque filters. Setting Pr6.43 “2-stage torque filter attenuation term” to 1000 (ζ=1.0), adjust Pr6.42 “2-stage
torque filter time constant”.
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...