2.2I/O connector output signal
2-7
(Note 7) The general-purpose output 1 (EX-OUT1) can be replaced with the contactor output (MC-OUT) of the power supply module only
for the Axis A of the driver module with the inter-module communication node address set to 1.
In addition, the following parameter settings are required:
<Relevant parameters>
Class No. Attribute Parameter name
Unit
Range
Function
7
24
C
Communication
function extended
setup 3
-
-32768
to
32767
bit 0 : EX-OUT1 output (MC-OUT output) setting when
EtherCAT communication is cut off
0: Hold output when communication is interrupted
1: Output initialization (OFF) when communication
is cut off
* The output will be OFF regardless of this setting until
the EtherCAT communication is established after the
power is turned on.
7
87
C
Communication
function extended
setup 5
-
-32768
to
32767
bit1: Power supply module contactor output switching
0: Use EX-OUT1 with general-purpose output 1
1: EX-OUT1 is used as the contactor output
(MC-OUT).
* This setting is valid only for the Axis A parameter of the
driver module whose module communication node
address is 1.
When the control power is turned on with the above settings, the contactor output (MC-OUT) of the power supply module can be
operated with the Axis A object 60FEh (Digital outputs) of the driver module with the inter-module communication node address
set to 1.
Symbol
Setting value
of Pr7.24
Setting value of
60FEh (Axis A)
State of output relay (PSM X101 connector MC1/MC2)
01h
(Physical
outputs)
02h
(Bit mask)
Reset
Communication
established
(Note 5)
Communication
intercepted
(Note 5)
Communication
re-established
(Note 5)
MC-
OUT
bit0 = 0
(hold)
0
0
MC-OUT = 0
(Relay open)
MC-OUT = 0
(Relay open)
MC-OUT = 0
(Relay open)
MC-OUT = 0
(Relay open)
1
0
1
MC-OUT = 0
(Relay open)
MC-OUT = 0
(Relay open)
MC-OUT = 0
(Relay open, hold)
MC-OUT = 0
(Relay open)
1
MC-OUT = 1
(Relay short)
MC-OUT = 1
(Relay short, hold)
MC-OUT = 1
(Relay short)
bit0 = 1
(initialization)
0
0
MC-OUT = 0
(Relay open)
MC-OUT = 0
(Relay open)
MC-OUT = 0
(Relay open)
MC-OUT = 0
(Relay open)
1
0
1
MC-OUT = 0
(Relay open)
MC-OUT = 0
(Relay open)
MC-OUT = 0
(Relay open)
MC-OUT = 0
(Relay open)
1
MC-OUT = 1
(Relay short)
MC-OUT = 1
(Relay short)
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...