Protective Functions
7-24
Error No.
Protective function
Causes
Measures
Main
Sub
88
0
Main power undervoltage
protection
(AC insulation detection
2)
On each axis of the driver module, the main
power AC cutoff (main circuit power supply
OFF) from the power supply module was
detected with the following settings.
Main circuit power supply OFF was
detected when the preset value of
6007h/6807h (Abort connection option
code) is 1 and the PDS state is "Operation
Enabled" or "Quick stop active".
Switch on command was received when
the preset value of 6007h/6807h (Abort
connection option code) is 1 and the PDS
state is "Ready to switch on" and main
circuit power supply OFF.
The capacity rise of power supply voltage.
A power supply is changed. The cause by
which the magnetic contactor of the main
power supply fell is removed, and a power
supply is switched on again.
Each phase (L1, L2, L3) of a power supply
is connected correctly. The single phase
100V and the single phase 200V should
use L1 and L3.
It replaces with new power supply module.
1
Control mode setting
error protection
In the driver module, the following incorrect
settings was detected for each axis.
The PDS state was changed to "Operation
enabled" when 6060h/6860h (Modes of
operation) was set to 0 and 6061h/6861h
(Modes of operation display) was set to 0.
6060h/6860h (Modes of operation) was
set to an unsupported control mode.
6060h/6860h (Modes of operation) was
set to 3 (pv), 4 (tq), 9(csv) or 10 (cst) in
full-closed control.
6060h/6860h (Modes of operation) was
set to 3 (pv), 4 (tq), 9(csv) or 10 (cst) in
two-degree-of-freedom control mode
(Synchronization type).
The control mode was set to
two-degree-of-freedom control mode
(synchronization type) in full-closed
control.
Check the preset value of 6060h/6860h
(Modes of operation).
Check the parameters Pr6.47 bit0 and bit3
related to two-degree-of-freedom control
mode.
2
ESM requirements
during operation error
protection
In the EtherCAT communication of the
driver module, the following incorrect
combinations occurred on each axis.
When PDS state was "Operation enabled"
or "Quick stop active", received the ESM
state change command to other ESM
states.
When Pr7.99 bit0=1 is set, the command
for transiting from the current ESM to
other ESM state was received during
servo-on (while warning D2 is occurring)
on PANATERM for Multi.
Check the state transition request from host
controller.
(To be continued)
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...