5.2Manual adjusting function
5-41
Class No.
Attribute
(Note 1)
Title
Range
Unit
Function
6
71
A
3rd damping depth 0 to 1000 -
Defines the depth against the 3rd damping frequency.
The depth becomes maximum if the setup value is 0. The larger
the setup value, the smaller the depth. Although the damping
effect increases as the depth becomes larger, the delay
becomes large. While the delay decreases as the depth
becomes smaller, the damping effect decreases.
Use this parameter to fine tune the damping effect and delay.
2
29
A
3rd damping width
setting
0 to 1000 -
Sets the width for the 3rd damping frequency. The enabled
range of setup is between 10 to 1000 and will operate as set to
100 between the range of 0 to 9. Within the setup range, the
width will increase with the increase in the setup value,
increasing robustness against vibration fluctuation.
2
20
B
4th damping
frequency
0 to 3000 0.1 Hz
You can set up the 4th damping frequency of the damping
control which suppresses vibration at the load edge.
The driver measures vibration at load edge. Setup unit is 0.1
[Hz]
The setup frequency is 0.5 to 300.0 [Hz]. Setup of 0 to 4
becomes invalid.
2
21
B
4th damping filter
setup
0 to 1500 0.1 Hz
If torque saturation occurs with damping frequency 4th enabled,
decrease the setup value, or if the operation is slow, increase it.
Usually set it to 0.
The maximum setup value is internally limited to the
corresponding damping frequency or 3000
–damping frequency,
whichever is smaller.
6
72
B
4th damping depth 0 to 1000 -
Defines the depth against the 4th damping frequency.
The depth becomes maximum if the setup value is 0. The larger
the setup value, the smaller the depth. Although the damping
effect increases as the depth becomes larger, the delay
becomes large. While the delay decreases as the depth
becomes smaller, the damping effect decreases.
Use this parameter to fine tune the damping effect and delay.
2
30
B
4th damping width
setting
0 to 1000 -
Sets the width for the 4th damping frequency. The enabled
range of setup is between 10 to 1000 and will operate as set to
100 between the range of 0 to 9. Within the setup range, the
width will increase with the increase in the setup value,
increasing robustness against vibration fluctuation.
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...