QUICK SETUP INSTRUCTIONS

FOR VARIABLE SPEED DRIVE

1 PHASE TO 3 PHASE

AND 

3 PHASE TO 3 PHASE

Connect Live to R and Neutral to S for single phase input

supply

Connections U/T1, V/T2, W/T3 go to the motor

Connect 3 phase input supply to L1/R, L2/S, L3/T

Connections U/T1, V/T2, W/T3 go to the motor

V/F curve set up

Factory setting is General purpose

HAMILTON PH: 07 847 3374
CHRISTCHURCH PH: 03 666 3374
[email protected]

AUCKLAND PH: 09 271 6063
[email protected]

For remote stop and start connect between DCM
and MI1 (FWD) and MI2 (REV) (DCM is your common)
For remote Potentiometer connect the pot to +10V,
AVI and ACM (common).

Set 

00.20

 to 2 (Remote Potentiometer)

Set 

00.21

 to 1 (Remote ON/OFF setting)

Set 

02.00

 to 1 or 2 (2-wire operation control)

Instructions for Remote Setup

(Remote On/Off and Speed Variation)

       

Set 02.00 to 3 (3-wire operation control)