9.1List of parameters
9-9
9.1.4 Class 3: Velocity/ Torque/ Full-closed control
No. Title
Unit
Range
Size
[byte]
Function/Contents
Attribute
Related
control
mode
Reference
04
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
05
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
12
Acceleration time
setup
ms/
(1000
r/min)
0 to
10000
2
Set the acceleration processing time
in response to the velocity
instruction input.
B
Velocity
13
Deceleration time
setup
ms/
(1000
r/min)
0 to
10000
2
Set the deceleration processing time
in response to the velocity
instruction input.
B
Velocity
14
Sigmoid
acceleration/
deceleration time
setup
ms
0 to 1000 2
Set the S-curve time for
acceleration/deceleration process
when the velocity instruction is
applied.
B
Velocity
17
Selection of speed
limit
-
2
2
Set the speed limit
B
Torque
21
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
22
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
23
External scale
selection
-
0 to 6
2
Select the type of external scale.
0: A,B phase output type
1: Serial communication type
(incremental specification)
2: Serial communication type
(absolute specification)
3 to 6:
For manufacturer’s use
R
All
24
Numerator of
external scale
division
-
0 to 2
23
4
Set up the numerator of the external
scale dividing setup.
When the set value = 0, the
operation is performed with the
encoder resolution used as the
division numerator.
R
Full-closed
25
Denominator of
external scale
division
-
1 to 2
23
4
Set up the numerator of the external
scale dividing setup.
R
Full-closed
26
Reversal of
direction of external
scale
-
0 to 3
2
When the set value = 0, the
operation is performed with the
encoder resolution used as the
division numerator.
R
All
27
External scale Z
phase
disconnection
detection disable
-
0 to 1
2
Validate/Invalidate Z-phase
disconnection detection when using
AB phase output type external
scale.
0: Valid
1: Invalid
R
All
28
Hybrid deviation
excess setup
Comman
d unit
1 to 2
27
4
Set the threshold of Err.25.0 (Hybrid
deviation excess error protection).
C
Full-closed
29
Hybrid deviation
clear setup
Revolutio
n
0 to 100
2
Clear hybrid deviation of each
revolution setting to zero.
C
Full-closed
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...