6.5Position comparison output function
6-13
Relevant parameters
Relevant parameters
Class No. Attribute Title
Range
Unit
Function
4
10
C
S
SO1 output
selection
-2147483648
to 2147483647
-
When using SO1 output as position compare output
(CMP-OUT), assign position compare output
(CMP-OUT: 14h) to Pr4.10 for all control modes.
A-axis position compare output : 1315860
(00141414h)
B-axis position compare output : 538186772
(20141414h)
* Do not make any other settings.
4
11
C
S
SO2 output
selection
-2147483648
to 2147483647
-
Set the function assignment for SO2 output.
The setting method is the same as Pr4.10.
4
44
R
Position
comparison output
pulse width setting
0 to 32767
0.1 ms
Set the pulse width of position comparison output.
No pulse is output when 0 is set.
4
45
R
Position
comparison output
polarity selection
0 to 7
-
Set the polarity of position comparison output by bit
setup for each output terminal.
Setup bits
bit0: SO1 , OCMP1
bit1: SO2 , OCMP2
Setup values of Each setting bit
0: The output photocoupler of SO1/SO2 turn ON, and
OCMP1/OCMP2 turn L level during pulse output.
1: The output photocoupler of SO1/SO2 turn OFF,
and OCMP1/OCMP2 turn H level during pulse
output.
4
47
R
Pulse output
selection
0 to 1
-
Set 1 to use the position comparison output signal
(COMP1/COMP2).
0: OCMP1/OCMP2 disabled
1: OCMP1/OCMP2 enabled
4
48
A
Position
comparison value
1
-2147483648
to 2147483647
Command
unit
Set the comparison value for position comparison value
1.
4
49
A
Position
comparison value
2
-2147483648
to 2147483647
Command
unit
Set the comparison value for position comparison value
2.
4
50
A
Position
comparison value
3
-2147483648
to 2147483647
Command
unit
Set the comparison value for position comparison value
3.
4
51
A
Position
comparison value
4
-2147483648
to 2147483647
Command
unit
Set the comparison value for position comparison value
4.
4
52
A
Position
comparison value
5
-2147483648
to 2147483647
Command
unit
Set the comparison value for position comparison value
5.
4
53
A
Position
comparison value
6
-2147483648
to 2147483647
Command
unit
Set the comparison value for position comparison value
6.
4
54
A
Position
comparison value
7
-2147483648
to 2147483647
Command
unit
Set the comparison value for position comparison value
7.
4
55
A
Position
comparison value
8
-2147483648
to 2147483647
Command
unit
Set the comparison value for position comparison value
8.
4
56
R
Position
comparison output
delay
compensation
amount
-32768 to
232767
0.1 us
Compensate the delay in the position comparison
output signaled by the circuit.
(To be continued)
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...