8.5Details of safety functions
8-13
8.5.3 Details of Safe Torque Off (STO)
8.5.3.1 Change point from MINAS-A5 series
MINAS-A5
MINAS-A6
STO
operation
Alarm generation
Err30.0
No Alarm
7-
segment LED is ”St”
Method of
releasing
the STO state
Release of the
factors
and
Alarm clear
After the STO state
status
When the alarm is
not generated
After the STO state
status
When the alarm is
generated
Release of the
factors of STO
and servo off
command
Release of the factors
of STO/alarm
and Alarm clear
8.5.3.2 Outline of safe torque off (STO) function
The safe torque off (STO) function is a safety function that shuts the motor current and turns off motor output torque by forcibly
turning off the driving signal of the servo driver internal power transistor.
When STO is activated, the servo driver turns off the servo-ready output signal (S-RDY) and goes into a STO state, with the
indication in the front panel turning to “St”. When STO input is released and servo-on input is Off, it will automatically transition
itself to Servo ready state.
Note) To ensure that the servo amplifier recognizes that STO has turned off, keep STO off for at least 8 ms.
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...