6.4Torque saturation protection function
6-11
6.4 Torque saturation protection function
If torque saturated has continued for a fixed period, an alarm can be activated.
Relevant parameters
Relevant parameters
Class No. Attribute Title
Range
Unit
Function
6
57
B
Torque saturation
anomaly detection
time
0 to 5000 ms
Set the torque saturation error protection detection time.
If torque saturation erroneously occurs for a set time, Err16.1
"Torque saturation error protection" occurs.
When 0 is set, the value set for Pr7.16 is enabled.
7
03
A
Output setup
during torque limit
0-1
-
Set up judgment condition of output while torque is limited by torque
control.
0: Turn ON at torque limit including torque command value
1: Turn ON at torque limit excluding torque command value
7
16
B
Frequency of
torque saturation
protection
0 to
30000
time
If torque saturated is continued during a preset frequency, Err 16.1
"Torque saturation protection" will be activated.
The number of times is counted up every 0.25 ms. For example,
when 30000 is set, Err16.1 occurs if the torque saturation condition
continues for 7.5 seconds.
The count is cleared when the torque saturation condition is
removed.
When the value set for Pr6.57 is other than 0, the value set for
Pr6.57 is enabled.
Set both Pr6.57 and Pr7.16 to 0 to make this function disabled.
When torque is controlled, this function is disabled and Err 16.1 will not be activated.
If the emergency stop alarm is activated, this function is disabled and Err 16.1 will not be activated.
During torque control, if Pr7.03 is 0, the torque limit signal output (TCL) is always ON.
Please set Pr7.03 to 1 to confirm torque limit signal output.
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...