![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879477.webp)
Menu Tables
FQ2-S4 User’s Manual
475
Ap
pend
ices
12
I/
O se
ttin
g
I/
O se
ttin
g
Ou
tpu
t
OUT0
to
OUT2
Control
signal
Used to assign output signals to OUT0,
OUT1, and OUT2.
OR (Total judgement) (default), BUSY,
ERROR, READY, RUN, STG
System
Item
judge-
ment
OR0 (Item0 judgement) to OR31 (Item31
judgement)
Expres-
sion
judge-
ment
Exp.0 judgement to EXP. 31 judgement
OR output
You can set the output conditions for the
OR signal and for output signals to which
judgements are assigned.
OK: ON or NG: ON (default)
System
Output mode
You can set the output mode for the OR
signal and for output signals to which
judgements are assigned.
One-shot output, Level output (default)
System
Output delay
When one-shot output mode is selected,
this parameter sets the delay from when
measurement processing is completed
until when the OR signal turns ON.
0 to 1,000 ms (default: 0 ms)
System
Output time
When one-shot output mode is selected,
this parameter sets the time that the OR
signal is ON.
1 to 1,000 ms (default: 5 ms)
System
BUSY output
Specifies when to turn OFF the BUSY
signal after starting measurement pro-
cessing.
Measurement (default), Data logging,
Image logging, or Result display
System
OUT0 Polarity
You can change the polarity of the output
signals that are assigned to OUT0 to
OUT2 (regardless of what signal is
assigned to the output).
Positive (default), Negative
System
OUT1 Polarity
Positive (default), Negative
System
OUT2 Polarity
Positive (default), Negative
System
BUSY LED
You can change the BUSY indicator to a
RUN indicator.
BUSY (default), RUN
System
Output control
You can select the data output method.
(Only when the FQ-SDU1
@
is con-
nected.)
None (default), Handshaking, or Sync.
Output
System
Menu command
Description
Setting range
Data
Refer-
ence
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......