Outputting Data and Controlling Operation through EtherNet/IP
FQ2-S4 User’s Manual
339
Con
necting
throu
gh
Eth
e
rnet
9
●
Settings in the FQ2 (Device Parameter Settings)
1
Right-click the FQ2 in the network on the Network Configurator and select [Parameter]
−
[Edit].
2
The Edit Device Parameters Dialog Box will be displayed. Make the required settings.
*1
Although the data size can be set as high as 502 bytes, with the current version set one of the following as the total data size for the output
area (data output size) and the response area (16 bytes).
• 48 bytes (default)
• 80 bytes
• 144 bytes
• 272 bytes
*2
Although the data size can be set as high as 502 bytes, with the current version use the default setting of 20 bytes.
*3
The packet interval (RPI) is set in the connection settings between the PLC and the Sensor. No setting is required here.
Parameter name
Value
Setting range
001 Input Size
*1
The total size of response area and output
area
48 to 272
002 Output Size
*2
The data size of command area
20
003 RPI
*3
The requested packet interval
10000