Adjusting the Judgement Parameters
220
FQ2-S4 User’s Manual
[
]
−
[Select the method.] on the right side of the display
There are no judgement condition settings for the following inspection items.
Bar code and 2D-code
You can select one of the following three patterns as the judgement method.
1) Threshold (minimum): The lower limit of the variations between OK object is used as the judgement
condition.
2) Threshold (average): The median value between the OK object variations and NG object variations is
used as the judgement condition.
3) Threshold (maximum): The upper limit of the variations between NG object is used as the judgement
condition.
Note
Measurement
value
Press [OK Teach] to register.