Controlling Operation and Outputting Data with TCP No-protocol Communications
406
FQ2-S4 User’s Manual
Setting the Output Format
[In/Out]
−
[I/O setting]
−
[Output data setting]
−
[Noprotocol data output]
1
Press [Output format].
2
Set [Output form] to [ASCII] or [Binary].
3
Set the data format for the data form that you select-
ed.
ASCII
Binary
Item
Description
Setting range
For ASCII
Digits of
integer
Sets the number of digits in the integer part
of the number.
1 to 10 digits
Default: 6 digits
Digits of
decimal
Set the number of digits in the integer part.
0 to 4 digits
Default: 4 digits
Negative
Sets the way to express negative numbers.
−
or 8
Default:
−
0 Sup-
pressed
Sets whether to use zero suppression.
Yes or No
Default: No
Field sepa-
rator
Sets the field separator.
OFF, comma, tab, space, CR, LF,
or CR+LF
Default: OFF
Record
separator
Sets the record separator.
OFF, comma, tab, space, CR, LF,
or CR+LF
Default: OFF
For Binary
Decimal
output form
Set the decimal output form for numerical
data.
Floating point or fixed point
(default: Fixed point)
▲
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......