Outputting Data and Controlling Operation through EtherNet/IP
330
FQ2-S4 User’s Manual
Data Exchange with EtherNet/IP
Data is exchanged cyclically between Ethernet devices on the EtherNet/IP network using tag data links as
shown below.
●
Data Exchange Method
To exchange data, a connection is opened between two EtherNet/IP devices.
One of the nodes requests the connection to open a connection with a remote node.
The node that requests the connection is called the originator, and the node that receives the request is called
the target.
●
Data Exchange Memory Locations
The memory locations that are used to exchange data across a connection are specified as tags.
You can specify memory addresses or variables for tags.
A group of tags consists of an output tag set and an input tag set.
Vision Sensor
Connection
PLC
Output tag set name: B
Output tag set name:
Input_101
Input tag set name: A
Ethernet (EtherNet/IP)
Target
Connection
Originator
Tag: D0
Tag: D100
Tag: Input_101
Connection from
FQ2 to PLC
Input tag set name:
Output_100
Tag:
Output_100
Connection from
PLC to FQ2
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......