![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879116.webp)
Reading Bar Codes
114
FQ2-S4 User’s Manual
Step 3
Setting Verification Conditions
You can register a character string from a barcode to use it to verify that the character string that was read from
a barcode matches the registered character string.
You can register up to 32 character strings for verification in the master data.
You can verify the character string in the inspection against up to 32 character strings that are registered in the
master data.
The verification result is saved in an external reference parameter, so you can use a communications
command to output it to an external device.
External Reference Parameters: p. 491
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Bar code]
−
[Settings] Tab Page
You can use the menu commands that are displayed for
at the right of the display to adjust the settings that
resulted from teaching.
[Camara setup]: You can adjust the Camera focus, brightness, and other factors to input a better image.
Adjusting Image Quality: p. 60
[Meas. Parameter]: You can change the type of code to read, the read settings, etc.
Detailed Parameters: p. 116
[Continuous test]: You can start test measurements of displayed images for the settings that were taught.
Performing Test Measurements: p. 214
1
Press [Verification].
2
Press [Master data regist.].
3
Press the character string to register in the master
data.
4
You can use any of the following three methods to
register character strings in the master data from the
menu display.
[Auto]:
Registers a character string from an actual
barcode in the master data. The procedure is
essentially the same as the procedure for
teaching in step 2.
[Manual]: Registers a character string that is entered di-
rectly in the master data. You can use a soft-
ware keyboard to register a character string
with up to 32 characters.
Note
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......