Logging Measurement Data and Image Data
256
FQ2-S4 User’s Manual
File Format
Image data: Image data is saved in a special format for OMRON Vision Sensors. (The file name extension is
IFZ.)
Measurement data: Measurement data is saved in the following CSV format.
*1:
The data and time are not recorded with the measurement data. Therefore, this is not the date that the measurement was executed. This
is the date that the PC Tool or the Touch Finder obtained the data from the Sensor.
Changing the Format for Saving Measurement Data
The output CSV file format can be changed according to the external device.
(Setup Mode or Run Mode)
−
[TF settings]
−
[File format]
−
[Logging data file]
1
Press [Output format].
2
Change the required items in the CSV format.
3
Press [Back].
Enabling File Logging
You must enable file logging before you can execute it.
(Setup
Mode)
−
[TF settings]
−
[Logging setting]
1
Press [ON].
Item
Format
Description
1)
Date
*1
YYYY/MM/DD
This is the date that the measurement data was obtained from
the Sensor.
2)
Time
*1
hh:mm:ss
This is the time that the measurement data was obtained from
the Sensor.
3)
Measurement ID
---
This is the measurement ID information.
4)
Scene No.
---
Scene number
5)
Judge
---
Overall judgement
0: OK,
−
1: NG,
−
2: NC (not measured)
6)
Inspection item
region
I(
inspection_item_number
).(
measure
ment_item
)(
detection_point
)
Example: The correlation of the sec-
ond detection point in a search for
inspection item number 0 would be
given as follows: I0.CR2
The data selected for logging in the [Measurement data] under
[Log setting] is output. If multiple results are detected, only the
maximum number of data items that is set in the [Measurement
data] are output.
7)
Expression region
Z0.D**
Example: The fourth registered
expression would be given as fol-
lows: Z0.D04
This is the expression results for each expression.
Item
Symbol
Field separator
None, comma (default), tabs, space, colon, semicolon, CR, or CR+LF
Decimal symbol
None, point (default), or comma
Record separator
None, comma, tabs, space, colon, semicolon, CR, or CR+LF (default)
1)
2)
3)
4)
5)
6)
7)
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......