Setting the Retry Function
276
FQ2-S4 User’s Manual
Auto scanning order
The scanning procedure when the sort order is set to auto is shown below.
1st
: The immediately previous scene that scanned successfully
2nd and following: Order of largest number of successful scans
• In the default state, the order is the order of the scene numbers.
• If the power is interrupted or the sensor is restarted, the success counts are initialized when adjust mode is entered.
Setting trigger retry
• Set the retry mode to [Trigger retry] in "Retry details".
(Setup
Mode)
−
[Sensor settings]
−
[Retry details]
To use trigger retry, the I/O input mode must be set to expanded mode.
[In/Out]
−
[I/O setting]
−
[I/O terminals]
−
[Input] tab
−
[Input mode]
Press "Expanded mode".
1
Press [Trigger retry] for the retry mode.
Scan condition of immediately
previous successful scan
Scene 1
Success count: 25
Scene 1
Success count: 25
Scene 2
Success count: 1
Scene 2
Success count: 1
Scene 3
Success count: 50
Scene 3
Success count: 50
Scene 4
Success count: 15
Scene 4
Success count: 15
Scene 5
Success count: 9
Scene 5
Success count: 9
Important
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......