![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879316.webp)
Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
314
FQ2-S4 User’s Manual
Offsetting the Timing of Outputting Measurement Results
The measurement result is output when the TRIG signal turns ON the number of times set for the [Number of
delay] parameter.
This allows you to delay the output timing of the measurement result from the Sensor according to the actual
processing timing of the line.
Example: Sequential Feed Line That Uses a Star Wheel
In a line like this, you can synchronize the output timing of the measurement results and the discharge timing of
NG products that are detected.
If you set the [Number of delay] parameter to 4, the measurement result output is delayed by four TRIG signals.
• With synchronized output, the number of times that the TRIG signal turns ON is counted. Therefore, use synchro-
nized output only when only one measurement result is output for each measurement. (Output either the parallel
judgement or data.)
• Use a measurement trigger only for single measurements.
If you perform continuous measurements by inputting a command, the output timing will not be correct and the
Sensor may malfunction.
3rd
Encoder
Result output
Discharge device
OR
TRIG
OK
NG
Sensor
4th
2nd
1st
Note
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......