Menu Tables
FQ2-S4 User’s Manual
469
Ap
pend
ices
12
Se
tt
in
g
(O
C
R
)
Ve
ri
fi
c
a
ti
o
n Verif. master data
Sets whether to verify the read charac-
ter string against a character string
that is registered in the master data.
Sets the character string to use to ver-
ify the read character string against
the master data.
OFF (default), All master data, or Mas-
ter data 0 to 31
Scene
Master data regist.
Registers a character string in the
master data.
Master data 0 to 31
Scene
[MENU]
Auto
Reads a character string from an input
image and registers it in the master
data.
---
Scene
Insp.
region
M
a
nua
l
L.1 to L.4 A character string is entered directly in
the master data.
32 alphanumeric characters
Scene
It
em ref
.
Ref. data Registers the immediately preceding
read results as a verification character
string.
---
Scene
L.1 verif.
range to
L.4 verif.
range
Sets the beginning and end characters
to verify.
1 to 1024 (defaults: beginning: 1, end:
1024)
Scene
Copy
Copies or clears registered master
data.
---
Scene
Delete
Auto teach No.
Sets the character string in the master
data in which to automatically register
the read result for teaching from an
external device.
OFF or Master data 0 to 31
Scene
(B
ar
code
, 2
D
-code
, 2D-
c
o
de
(DPM))
Verif. master data
Sets whether to verify the read charac-
ter string against a character string
that is registered in the master data.
Sets the character string to use to ver-
ify the read character string against
the master data.
OFF, All master data (default), or Master
data 0 to 31
Scene
Master data regist.
Registers a character string in the
master data.
Master data 0 to 31
Scene
[ME
NU]
Auto
Reads a character string from an input
image and registers it in the master
data.
---
Scene
Insp.
region
M
a
nua
l
L.1 to L.4 Registers a character string directly in
the master data.
32 alphanumeric characters
Scene
It
em ref
.
Ref. data Registers the immediately preceding
read results as a verification character
string.
---
Scene
Line 1
verif.
range to
Line 4
verif.
range
Sets the beginning and end characters
to verify for each line.
1 to 1024 (defaults: beginning: 1, end:
1024)
Scene
Copy
Copies or clears registered master
data.
---
Scene
Delete
Menu command
Description
Setting range
Data
Refer-
ence
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......