![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879181.webp)
Inspecting with Color Data Inspection Item
FQ2-S4 User’s Manual
4
Setting Up
Inspect
ions
179
Step 2
Teaching
Teaching means to store the region and the average color in the region as reference data for the measurement.
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Color Data]
−
[Settings] Tab Page
The following data is stored as the measurement reference.
Step 3
Adjusting Judgement Parameters
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Color Data]
−
[Settings] Tab Page
1
Press [Teach].
2
Place the object that is to be used as the measure-
ment reference in front of the camera.
3
Move the rectangle to the location to be measured.
4
Press [OK].
5
Press [TEACH] on the lower right of the display.
The basic settings will be registered when teaching has
been completed.
6
Press [Back] to end teaching.
Changing the measurement region: p. 144
Item
Parameter
Description
Reference data
Hue
The hue to use as a reference is set automatically.
Saturation
The saturation to use as a reference is set automatically.
Brightness
The brightness to use as a reference is set automatically.
1
Press [Judgement].
2
Press the parameters and set the range that is to be
judged as OK.
The measured value is displayed beside the parameter
name. Continuous measurements will be performed for
the images that are displayed.
3
Press [OK] to enter the value.
Drag a corner to size the rectangle.
Drag the rectangle to move it.
Blue for OK. Red for NG.
Lower limit
Upper limit
You can change the parameters for judgement conditions on the
Display Settings Display. Press [
]
−
[Display setting] on the right
of the display to switch to the Display Settings Display.
Note
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...