Outputting Data and Controlling Operation through EtherNet/IP
332
FQ2-S4 User’s Manual
●
Data Output after Measurements
Immediately after a single measurement or continuous measurements, the Vision Sensor will automatically
output the data for the measurements that are specified for output in advance to the I/O memory addresses or
variable that is specified for the input tag in the PLC.
This enables you to easily transfer the measurement results data for inspection items to the PLC.
When handshaking is enabled, the data is output from the Vision Sensor only when the condition to receive
that data are met at the PLC.
To output data, you must specify in advance the data to output (up to 64 items) after the measurements are
executed.
To output character strings that are read with the OCR and other inspection items, the character strings to
output are also specified in advance. You must also specify in advance the output area (i.e., I/O memory
addresses or variable) for the input tag to store the data in the PLC.
After a single measurement or continuous measurements, the data is automatically stored in the output area
(i.e., I/O memory addresses or variable) that is specified for the input tag in the PLC via the connection from the
Vision Sensor to the PLC.
PLC
Vision Sensor
Output area
I/O memory or variables
(communications areas)
Built-in EtherNet/IP port in CPU Unit
EtherNet/IP (tag data links)
Up to 64 specified data items
can be automatically output.
Output connection to PLC
Data
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......