PLC Link Connections
FQ2-S4 User’s Manual
389
Con
necting
throu
gh
Eth
e
rnet
9
●
Data Acquisition/Setting Commands
Command Details
●
Single Measurement (Command Code: 1010 0010)
Command (PLC to Vision Sensor)
Response (Vision Sensor to PLC)
First word of com-
mand area (hex)
Command name
Function
Reference
+2
+3
1010
0040
Get Image Adjustment Data
Acquires data from a position compensation
item or filter item.
1010
0050
Set Image Adjustment Data
Sets the specified data in a position compen-
sation item or filter item.
1020
0040
Get Inspection Item Data
Acquires the inspection item data.
1020
0050
Set Inspection Item Data
Sets the inspection item data to the specified
data.
3000
0040
Get Software Version Informa-
tion
Acquires the software version.
5000
0020
Get Latest Error Information
Acquires the latest error information.
First word of
command
area
Bits
Contents
12 to 15
8 to 11
4 to 7
0 to 3
+2
0001
0000
0001
0000
Command code: 4-byte binary
data
+3
0000
0000
0001
0000
First word of
response area
Bits
Contents
12 to 15
8 to 11
4 to 7
0 to 3
+2
0001
0000
0001
0000
Command code
The command code for which the
response applies is stored.
+3
0000
0000
0001
0000
+4
0000
0000
0000
0000
Response code
Command execution result
0: OK, FFFFFFFF: NG
+5
0000
0000
0000
0000
The measurement results are written to the output area if data output is set.
The measurement results are not output if data output is not set.
Setting the Data To Output Automatically after Measurements: p. 377
Note
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......