PLC Link Connections
384
FQ2-S4 User’s Manual
Increment from first
address in output area
Output data
Assigned output data
+0
Data 0 (4 bytes)
Inspection item 0: Number of characters
+1
+2
Data 1 (4 bytes)
Inspection item 1: Number of characters
+3
+4
‘A’
Inspection item 0: Characters “ABC”
+5
‘B’
+6
‘C’
+7
‘0’
Inspection item 1: Characters “0123”
+8
‘1’
+9
‘2’
+10
‘3’
+11
00
Filled with zeros. (Only when the character string length is
not a multiple of 4.)