![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879186.webp)
Inspecting with the Area Inspection Item
184
FQ2-S4 User’s Manual
Reflect in Total Judgement
You can specify whether to reflect the judgement results of an inspection item in the overall judgement. (The
default is to reflect them.)
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Area]
−
[Details] Tab Page
−
[Output parameter]
Unstable Area Results
The Desired Color Cannot Be Detected
Add a specific color or enlarge the color range.
Extraction Is Automatically Performed for an Undesired Color When Teaching
Manually set the color for which to measure the area.
[Inspect]
−
[Inspection]
−
[Area]
−
[Modify]
−
[Settings] Tab Page
−
[Teach]
• Sensors with Color Cameras Only
Item
Parameter
Setting
Description
Judgement Parameter
Area
Range: 0.00000 to 999,999,999.9999
Default: Upper limit: 999,999,999.9999,
Lower limit: 0.0000
Set the upper and lower limits for an OK
judgement. The set range is the differ-
ence between the reference area and
the measured areas.
Gravity X
Range:
−
999,999,999.9999 to
999,999,999.9999
Default: Upper limit: 999,999,999.9999,
Lower limit:
−
999,999,999.9999
Set the upper and lower limits of the
range of gravity X that is to be judged
as OK.
Gravity Y
Range:
−
999,999,999.9999 to
999,999,999.9999
Default: Upper limit: 999,999,999.9999,
Lower limit:
−
999,999,999.9999
Set the upper and lower limits of the
range of the gravity Y that is to be
judged as OK.
• You can change the output form for each measurement value to one of the following settings.
Press
[
]
−
[Result type] on the right of the display.
Absolute value (default): The measured coordinates are output.
Relative value: The difference from the reference position is output as coordinates.
Ratio: The percentage of the reference value is output. (This applies to the area only.)
1
Press [
]
−
[Set color] on the right of the display.
2
Drag around the color for which you want to measure
the area.
Areas with that color will be automatically detected.
Continuous measurements will be performed for the im-
ages that are displayed.
Only the extracted color will appear on the display.
3
Press [OK].
4
Press [TEACH].
5
Press [Back] to end teaching.
Note
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......