Calculation
Se
tt
in
g
s
Expression
[MENU]
Expression 0 to
expression 31
Sets the number of the expression for
which to set a calculation.
---
Scene
Expression set-
tings
Sets the expressions.
---
Scene
Data
Uses the measurement result of other
items.
Inspection item, calculation symbols ( ( )
/ * . , + TJG)
Scene
Const.
Inputs constants or mathematical
operators.
0 to 9, ., calculation symbol ( ( ) / * ? , +
TJG)
Scene
Math.
Uses functions in expressions.
SIN, COS, ATAN, AND, OR, NOT, ABS,
MAX, MIN, MOD, SQRT, ANGL (angle
of straight line joining two points (center
of gravity and model center)), DIST (dis-
tance between two points), calculation
symbols ( ( ) / * . , + TJG)
Scene
Rename
Deletes/copies the expression or
changes the expression name.
---
Scene
Copy
---
Scene
Delete
---
Scene
Judgement
Specifies the parameters for judge-
ment of results.
Scene
Details
Out
put
par
amet
er Reflect
You can specify whether to reflect the
judgement results of a calculation in
the overall judgement.
No, Yes (default),
Scene
Retr
y
de
tai
ls Max Count
(Normal retry)
Sets the number of retries.
0 to 8, Default: 4
Scene
Interval
(Normal retry)
Sets the retry interval (msec).
32 to 999, Default: 100
Scene
Brightness step or Shutter
speed step
(Exposure retry)
Sets the exposure time step (msec).
Brightness step:
1 to 20, Default 2
shutter speed step:
0.01 to 1.00 (Default: 1.00)
Scene
Increment count
(Exposure retry)
Sets the increment count for the
brightness (shutter speed) step.
0 to 10, 2 (default)
Scene
Decrement count
(Exposure retry)
Sets the decrement count for the
brightness (shutter speed) step.
0 to 10, 2 (default)
Scene
Menu command
Description
Setting range
Data
Refer-
ence
Log
set
ti
ng Statistical data
Sets whether to record the number of
measurements and the number of NG
overall judgements.
ON (default) or OFF
System
Image logging
Sets the parameter to log measurement
image data.
All, Only NG, or None (default)
System
Data log-
ging
Condition
Sets the parameter to log measurement
data from inspection items.
All, Only NG, or None (default)
System
Select data
You can select the parameters to log
from the parameters in the filter items,
position compensation items, inspection
items and expression that are set.
Parameter names for the filter items,
position compensation items, inspection
items and expression that are set
System
Delete Log
Resets the log data without turning OFF
the power supply.
---
System
Menu command
Description
Setting range
Data
Refer-
ence
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......