Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
326
FQ2-S4 User’s Manual
Saving Data in the Sensor
This command saves the current settings (scene data and system data) in the Sensor.
Parameters
Timing Chart
Output Signals
Input Signals
Execution
Command
Input example
IN7
IN6
IN5
IN4
IN3
IN2
IN1
IN0
1
101000
1101000
Signal
Function
RUN
This signal is ON while the Sensor is in Run Mode. It will be OFF in Setup Mode.
BUSY
This signal will be ON while data is being saved in the Sensor.
ACK
When the command has been completed normally, this signal is turned ON for the time that is set for the ACK
output time.
Signal
Function
IN1 to IN3
Turn OFF.
IN4
Turn ON.
IN5
Turn OFF.
IN6
Turn ON.
IN7
This signal is the trigger for saving data in the Sensor.
Set the IN0 to IN6 signals, wait for at least 5 ms, and then turn ON the IN7 signal.
0
IN7 signal
OFF
ON
OFF
ON
RUN signal
OFF
ON
IN0 to IN6
signals
Run Mode entered.
Setup Mode entered.
BUSY signal
101000
Allow 5 ms min.
and then turn ON IN7.
ON for 1 ms min.
Command execution
ACK signal
OFF
ON
ACK output time
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......