Inspecting with the Search Inspection Item
FQ2-S4 User’s Manual
4
Setting Up
Inspect
ions
139
Increasing Measurement Position Accuracy
You can increase the accuracy of measurement positioning.
You can calculate down to four decimal places.
[Inspect]
−
[Inspection]
−
[Search]
−
[Modify]
−
[Details] Tab Page
−
[Meas. Parameter]
Obtaining Multiple Results Simultaneously
You can detect all items that satisfy the extraction conditions.
Judgement is performed for all detected results.
[Inspect]
−
[Inspection]
−
[Search]
−
[Modify]
−
[Details] Tab Page
−
[Meas. Parameter]
• You can change the output form for each measurement value to one of the following settings.
Press
[
]
−
[Result type] on the right of the display.
Absolute value (default): The measured coordinates are output.
Relative value: The difference from the reference position is output as coordinates.
1
Press [Sub-pixel] and select [Yes].
1
Press [Multi-point output] and select [Yes].
2
Press [Sorting method] and select the conditions by
which to sort the detected results.
You can output the results in the sort order that you se-
lected.
Selection item
Setting
Description
Sorting method
Corr. ascending order (ascending order of correlation
value)
Sorts the results in order from the smallest correlation
to the largest.
Corr. descending order (descending order of correlation
value)
Sorts the results in order from the largest correlation to
the smallest.
Pos.X ascending order (ascending order of position X)
Sorts the results in order from the smallest measure-
ment X position to the largest.
Pos.X descending order (descending order of position X)
Sorts the results in order from the largest measure-
ment X position to the smallest.
Pos.Y ascending order (ascending order of position Y)
Sorts the results in order from the smallest measure-
ment Y position to the largest.
Pos.Y descending order (descending order of position Y)
Sorts the results in order from the largest measure-
ment Y position to the smallest.
Note
You can specify the actual output conditions and count for output-
ting multiple results.
Selecting the results to output: p. 140
Note
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......