![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879290.webp)
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
288
FQ2-S4 User’s Manual
Timing Chart
Output OR0 to OR31 signals are held until the next judgement output.
*1: The timing for updating the OR signal is when the measurement results are finalized, regardless of the output settings of the BUSY signal
(BUSY output conditions).
Settings
[In/Out]
−
[I/O setting]
−
[I/O setting]
−
[Output]
1
Press [OUT0].
2
Press [OR2 (Item 2 judgement)].
OR2 output signal was assigned to OUT0.
3
Assign the others in the following manner.
OUT1: OR5
OUT2: OR14
Adjusting the Judgement Output Timing
The output timing of the OR signal or OR0 to OR31 signals can be selected from two modes depending on the
external device.
Selecting the OFF Timing
• Level output (default)
The status of the output OR signal is held until the next OR signal is output.
OFF
ON
OFF
ON
OR1 signal
Turned ON when individual
judgement is NG.
(OR output: ON for NG)
OR0 signal
Turned ON when individual
judgement is NG.
(OR output: ON for NG)
Example:
ON while measurements are
being processed (depends
on BUSY output conditions)
BUSY signal
TRIG signal
ON for 1 ms min.
Individual
judgement
*1
OFF
ON
OFF
ON
OFF
ON
NG
OK
Held until the next
judgement result is output
Overall judgement
(OR output: ON for NG)
OR signal
ON while measure-
ments are being
processed (depends
on BUSY output
conditions)
BUSY signal
TRIG signal
ON for 1 ms min.
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......