Menu Tables
FQ2-S4 User’s Manual
485
Ap
pend
ices
12
Se
nsor se
tt
ings
Da
ta ou
tpu
t
Li
nk da
ta
ou
tpu
t
Ar
ea se
tt
ings
Response
Are
a
t
y
pe
Sets the area to write execution results
from the Sensor.
Control outputs, command codes,
response codes, and response data
PLC Link (SYSMAC CS/CJ/CP/One)
CIO Area (CIO) (default), Work Area
(WR), Holding Bit Area (HR), Auxiliary
Bit Area (AR), DM Area (DM), EM Area
(EM0 to EMC)
PLC Link (MELSEC QnU/Q/QnAS)
Data Register
File Register
Link Register
System
A
ddress
Set the first address of the response
area.
0 to 99999 (default: 100)
System
Out
put
Area
t
y
pe
Sets the area to write output data from
measurements.
Output data 0 to 31
PLC Link (SYSMAC CS/CJ/CP/One)
CIO Area (CIO) (default)
Work Area (WR)
Holding Bit Area (HR)
Auxiliary Bit Area (AR)
DM Area (DM)
EM Area (EM0)
EM Area (EM1)
:
EM Area (EMC)
PLC Link (MELSEC QnU/Q/QnAS)
Data Register
File Register
Link Register
System
Addr
ess
Set the first address of the output area .
0 to 99999 (default: 200)
System
Output hand-
shake
Sets whether to establish an interlock
with the PLC when data is output.
No (default) or Yes
System
Retry details
Enables or disables retrying communica-
tions.
This can be set only when the communi-
cations type is set to a PLC Link.
ON or OFF (default)
System
Retry interval
Sets the interval for retrying communica-
tions.
This setting is enabled only when [Retry
details] is set to [ON].
This can be set only when the communi-
cations type is set to a PLC Link.
0 to 2,147,483,647 ms (default:10,000
ms)
System
Max output data
Sets the upper limit of the number of out-
put data to use for PLC Link outputs.
Any output data that is beyond this value
is discarded.
This can be set only when the communi-
cations type is set to a PLC Link.
32 to 1024 (default: 256)
System
Output data size
Sets the data size to output for EtherNet/
IP output.
If the data size that is set is exceeded,
data will be output in more than one
transfer.
This can be set only when the communi-
cations type is set to EtherNet/IP.
32 bytes (default), 64 bytes, 128 bytes, or
256 bytes
System
Connection
mode
Sets the TPC connection mode.
TCP server (default) or TCP client
System
Refreshing task
period
Set the communications cycle for cyclic
tag data link communications for the
Vision Sensor.
This can be set only when the communi-
cations type is set to EtherNet/IP.
1 to 10,000 ms (default:10 ms)
System
Timeout
Sets the timeout time when handshaking
is enabled.
This can be set only when the communi-
cations type is set to EtherNet/IP.
0.1 to 120.0 s (default: 10 s)
System
Menu command
Description
Setting range
Data
Refer-
ence
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......