Inspecting with the Edge Pitch Inspection Item
FQ2-S4 User’s Manual
4
Setting Up
Inspect
ions
175
Changing Edge Detection Conditions (Sensors with Monochrome Cameras Only)
You can change the following measurement conditions for Sensors with Monochrome Cameras.
[Inspect]
−
[Inspection]
−
[Edge Pitch]
−
[Modify]
−
[Details] Tab Page
−
[Meas.parameter]
Reflect in Total Judgement
You can specify whether to reflect the judgement results of an inspection item in the overall judgement. (The
default is to reflect them.)
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Edge Pitch]
−
[Details] Tab Page
−
[Output parameter]
Unstable Edge Pitch Results (Sensors with Color Cameras Only)
If the measurement result is not stable, adjust the [Edge level], [Noise level], and [Set color.] parameters.
Increasing Edge Pitch Processing Speed
Make the measurement region smaller to reduce the processing time.
Changing the measurement region: p. 144
Item
Parameter
Setting
Description
Judgement Parameter
Edge pitch
Range: 0 to 1000
Defaults: Lower limit: 0,
Upper limit: 1000
Set the range that is to be judged OK
for each parameter.
Average pitch
Range: 0.0000 to 99,999.9999
Defaults: Lower limit: 0.0000,
Upper limit: 99,999.9999
Max. pitch (maximum
pitch)
Range: 0.0000 to 99,999.9999
Defaults: Lower limit: 0.0000,
Upper limit: 99,999.9999
Min. pitch (minimum
pitch)
Range: 0.0000 to 99,999.9999
Defaults: Lower limit: 0.0000,
Upper limit: 99,999.9999
Average width
Range: 0.0000 to 99,999.9999
Defaults: Lower limit: 0.0000,
Upper limit: 99,999.9999
Max. width (maximum
pitch)
Range: 0.0000 to 99,999.9999
Defaults: Lower limit: 0.0000,
Upper limit: 99,999.9999
Min. width (minimum
pitch)
Range: 0.0000 to 99,999.9999
Defaults: Lower limit: 0.0000,
Upper limit: 99,999.9999
Parameter
Setting
Description
Color to count
White (default)
Black
Sets the color of edges to measure.
Mode
Standard (default)
Precise
Select the Precise Mode if the pin width or pitch is less than 2 pixels.
Edge pitch (number of objects)
Pitch
(distance between
center points)
Width
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......