Menu Tables
486
FQ2-S4 User’s Manual
Se
nsor se
tt
ings
Da
ta ou
tpu
t
Li
nk da
ta
ou
tpu
t
Data output
period
Set the period for outputting measure-
ment results.
This parameter is displayed and can be
set only when [Handshake setting] is set
to [No].
This can be set only when the communi-
cations type is set to EtherNet/IP.
2 to 5,000 ms (default: 40 ms)
System
GATE signal ON
period
Set the time to turn ON the GATE signal.
This parameter is displayed and can be
set only when [Handshake setting] is set
to [No].
This can be set only when the communi-
cations type is set to EtherNet/IP.
1 to 1,000 ms (default: 20 ms)
System
Communication
mode
This parameter is displayed and can be
set only when [Comm. type] is set to
[PLClink (MELSEC)].
TCP server (default) or TCP client
System
Initialize
Initializes the Sensor settings and saved
data.
---
---
Restart
Restarts the Sensor.
---
---
Update
Updates the Sensor system to the most
recent data.
---
---
Menu command
Description
Setting range
Data
Refer-
ence
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......