![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879302.webp)
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
300
FQ2-S4 User’s Manual
Executing External Teaching
You can use the image that is currently being input to execute teaching for all of the registered inspection items.
Settings
[In/Out]
−
[I/O setting]
−
[I/O setting]
−
[Input]
−
[Input mode]
Press [Expand mode].
Wiring
Timing Chart
• Application is possibly only from the Run Mode
• If the parameter is applicable to more than one inspection item, it will be external teaching for all inspection items.
Color
Signal
State
Description
The signals shown at the left are
used.
Refer to the following information for
signal wiring.
Gray
IN0
ON
Command parameter for external teaching
Green
IN1
OFF
Red
IN2
OFF
White
IN3
ON
Purple
IN4
OFF
Yellow
IN5
ON
Command input for external teaching
Orange
OUT1 (BUSY)
--
Processing in progress (default)
1 Turn ON IN0 and IN3 and turn OFF
IN1, IN2, and IN4.
2 Turn ON the IN5 signal while the
BUSY signal is OFF to execute
external teaching.
3 The BUSY signal turns ON while
external teaching is being executed.
Note
OFF
ON
OFF
ON
Start external teaching
End external teaching
BUSY signal
IN5 signal
ON for 1 ms min.
Allow 5 ms min. and then
turn ON IN5.
IN0 to IN4 signals
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......