Reading DPM 2D Codes
FQ2-S4 User’s Manual
4
Setting Up
Inspect
ions
129
Step 2
Teaching
For teaching, the region to measure and the 2D code within that region are set as read conditions. You can also
register the contents that was read from the 2D code as a verification condition in the master data.
Step 4 Setting the Verification Conditions: p. 131
[Inspect] - [Inspection] - [Add item.] - [2D-code (DPM)] - [Settings] Tab Page
1
Press [Teach].
2
Display the image of the 2D code.
3
Move the rectangle so that it surrounds the 2D code.
4
Press the [OK] Button.
5
Press [TEACH] on the lower right of the display.
6
The result of reading the 2D code that was displayed
will be displayed along with a confirmation dialog box
for registration in the master data.
7
Press [Yes] to register the read result in the master
data.
The master data contains the character strings from the
2D codes that are registered to verify whether the read
character strings match specific character strings.
8
Press [Back] to end teaching.