Setting the Retry Function
274
FQ2-S4 User’s Manual
Setting normal retry
• Set the retry mode to [Normal retry] in "Retry details".
(Setup
Mode)
−
[Sensor settings]
−
[Retry details]
• Specify the maximum count and interval.
[Inspect]
−
[Retry details]
Setting exposure retry
• Set the retry mode to [Exposure retry] in "Retry details".
(Setup
Mode)
−
[Sensor settings]
−
[Retry details]
• Set the brightness (shutter speed) step, increment count, and decrement count.
[Inspect]
−
[Retry details]
1
Press [Normal retry] for the retry mode.
2
Press OK.
1
Set the maximum count and interval.
Parameter
Settings
Description
Max count
0 to 20, (default: 4)
Sets the maximum number of retries.
Interval
32 to 999, (default: 100)
Sets the capture interval (msec).