![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879419.webp)
Controlling Operation and Outputting Data with TCP No-protocol Communications
FQ2-S4 User’s Manual
417
Con
necting
throu
gh
Eth
e
rnet
9
●
MODEL
Re-register Models
This command re-registers the models for registered Search and Color Data inspection items.
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
●
RESET
Resets the Sensor
This command resets the Sensor.
<Command Format>
<Response Format>
When the Command Is Processed Normally
If process is completed normally, the Sensor is restarted. There is therefore no response.
When the Command Is Not Processed Normally
M
O
CR
D
E
L
Command
Delimiter
CR
O
K
Delimiter
CR
E
R
Delimiter
R
E
CR
S
E
T
Command
Delimiter
CR
E
R
Delimiter
Summary of Contents for FQ2-S4