Inspecting with the Area Inspection Item
186
FQ2-S4 User’s Manual
Changing the Area Detection Conditions
You can fill in the area detected through color extraction or binary conversion to perform a stable extraction of
the areas and their characteristics or to mark only areas inside the measurement region for inspection.
[Inspect]
−
[Inspection]
−
[Aria]
−
[Modify]
−
[Details] Tab Page
−
[Meas. Parameter]
Increasing Processing Speed for Area
Make the measurement region smaller to reduce the processing time.
Changing the measurement region: p. 144
1
Press [Fill profile] and select [Filling up holes] or [Fill
Outline].
Item
Parameter
Setting
Description
Meas.Parame-
ter (measure-
ment
parameter)
Fill profile
Filling up holes
Fill Outline
None
Default: None
None: Holes are not filled.
Filling up holes: Processes areas that are surrounded by the specified
color, like in the shape of a donut, as the specified color.
Fill Outline:
Measures the image between the first extracted point and the last
extracted point in the X axis direction in the measurement area as the
extracted color.
Because filling is performed only in the X axis direction, this method is
faster than filling up holes.
Input Image
Filled Image
Input Image
Image Following Fill Outline
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......