![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879438.webp)
Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
436
FQ2-S4 User’s Manual
Resetting the Sensor: 280F 0010F010
This command resets the Sensor.
●
Format
●
Response Format
If process is completed normally, the Sensor is reset. There is therefore no response.
External Teaching: 280F 00104020
This command performs teaching for all applicable inspection items.
●
Format
●
Response Format
●
End Codes
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
28
0F
0010F010
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
28
0F
00104020
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
28
0F
End code
00104020
End code (hex)
Meaning
0000
Command execution ended normally.
FFFF
Command execution ended in an error.