Display Functions
246
FQ2-S4 User’s Manual
Change the following setting to display the last NG image after restarting.
(Setup Mode or Run Mode)
−
[TF Settings]
−
[Startup display]
−
[Display update mode]
Automatically Changing to the Display for Any Sensor with an NG Result
You can change the settings to automatically display the Sensor for which the measurement result is NG if
more than one Sensor is connected.
(Run Mode)
−
[Sensor monitor]
−
[NG Sensor]
Hiding the Menu
You can hide the menu and display only the image on the Touch Finder or PC Tool to check the part of the
image hidden behind the menu.
If you press the icon again, the menu will be displayed.
(Setup Mode or Run Mode)
Turning ON/OFF the Touch Finder Backlight
You can use Eco Mode to turn OFF the LCD backlight and reduce the power consumed by the Touch Finder
whenever there is no operation on the Touch Finder for 30 seconds or longer. The LCD backlight will turn ON
whenever any part of the touch panel is pressed.
(Setup Mode or Run Mode)
−
[TF settings]
−
[LCD Backlight]
−
[ECO mode]
Changing the Brightness of the Touch Finder
The brightness of the LCD backlight can be changed to any of five levels.
(Setup Mode or Run Mode)
−
[TF settings]
−
[LCD Backlight]
−
[Brightness]
1
Press [Last NG image].
If an operation to change the display is performed (e.g., if the display pattern is changed or the inspection item is
changed) when displaying images for NG results is set, the display will change to refreshing the most recent mea-
surement results and the most recent NG display will disappear.
To ensure that you can check the NG results, log the NG results.
Checking Recent Measurement Trends (Recent Results Logging): p. 258
Note
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......