Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
322
FQ2-S4 User’s Manual
Re-registering the Model and Reference Color
This command is input from an external devices, such as a PLC, to re-register the models and reference colors
for registered inspection items based on the image that was just input.
Parameters
Timing Chart
Output Signals
Inspection items
Re-registered data
Search, Shape Search II, Sensitive Search, Search Position Compensation, and
Shape Search Position Compensation
Models
Color Data
Reference color (hue, saturation, and brightness)
Edge Position, Edge Width, Edge Pitch, Area, and Labeling
None
Execution
Command
Input example
IN7
IN6
IN5
IN4
IN3
IN2
IN1
IN0
1
1001000
11001000
Signal
Function
RUN
This signal is ON while the Sensor is in Run Mode. It will be OFF in Setup Mode.
BUSY
This signal is ON during re-registration of the model and reference color.
ACK
When the command has been completed normally, this signal is turned ON for the time that is set for the ACK output time.
0
IN7 signal
OFF
ON
OFF
ON
RUN signal
OFF
ON
IN0 to IN6 signals
Run Mode entered.
Setup Mode entered.
BUSY signal
Command execution
11001000
Allow 5 ms min.
and then turn ON IN7.
ON for 1 ms min.
ACK signal
OFF
ON
ACK output time
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......