Menu Tables
484
FQ2-S4 User’s Manual
Se
nsor se
tt
ing
s
Da
ta ou
tpu
t
No-
p
rotocol data
Communication
type
Sets the communications type to use to
output no-protocol data.
Invalid (default), No protocol (TCP), No
protocol (FINS), No protocol (RS-232C)
System
When the com-
munications type
is TCP no-proto-
col or FINS/TCP
no-protocol
Connec-
tion mode
Sets whether to communicate with the
communications devices as a server
device or a client device.
TCP server (default), TCP client
System
IP address Sets the IP address to which to output
no-protocol data.
* Setting is not possible if the connection
mode is set to a TCP server.
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 1 to 254
(Default:10.5.5.111)
System
Port No.
Sets the output port number.
* Setting is not possible if the connection
mode is set to a TCP server.
0 to 65535 (Default: 9600)
System
Dat
a
out
put
No-p
rot
o
col dat
a When the com-
munications type
is RS-232C no-
protocol
Baud rate
Set the baud rate to use for RS-232C
communications.
2400, 4800, 9600, 19200, 38400, 57600,
or 115200 (default: 38400)
System
Data
length
Sets the data length.
7bit or 8bit (default: 8bit)
System
Parity
Sets the parity.
None, Odd, Even (default: None)
System
Stop bit
Sets the number of stop bits.
1bit, 2bit (default: 1bit)
System
Flow con-
trol
Sets the controls for the flow of commu-
nications with the software.
None, Xon/Xoff (default: None)
System
Delimiter
Set the delimiter to add to the end of
commands and responses.
CR, LF, or CR+LF (default:CR)
System
Interval
timeout
(text)
Timeout [s] Set the time in seconds to
generate a timeout error.
1 to 120 s, 0: Not monitored.
(default: 0 s)
System
Interval
time-
out(after
Xoff
reception)
Timeout [s] Set the time in seconds to
generate a timeout error.
1 to 120 s, 0: Not monitored.
(default: 0 s)
System
Li
n
k
da
ta
ou
tp
u
t
Communication
type
Sets the communications type to use for
EtherNet/IP or PLC Link outputs.
Invalid (default), PLC link (SYSMAC)
PLC link (MELSEC), EtherNet/IP
System
Area set-
tings(Only when
communications
type is PLC Link)
Comman
d
A
rea t
y
p
e
Sets the area to write command data to
the Sensor.
Control inputs, command codes, and
command parameters are written to this
area.
PLC Link (SYSMAC CS/CJ/CP/One)
CIO Area (CIO) (default)
Work Area (WR)
Holding Bit Area (HR)
Auxiliary Bit Area (AR)
DM Area (DM)
EM Area (EM0 to EMC)
PLC Link (MELSEC QnU/Q/QnAS)
Data Register
File Register
Link Register
System
Addr
ess
Set the first address of the command
area.
0 to 99,999 (default: 0)
System
Menu command
Description
Setting range
Data
Refer-
ence
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......