![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879289.webp)
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
FQ2-S4 User’s Manual
287
8
Controll
ing
Ope
rati
on a
nd Outputting
Data
wi
th
a
Para
llel
Co
nne
ctio
n
Getting Individual Judgements and Expression Judgements
Up to three judgement results of individual inspection items (item judgement signals OR0 to OR31) and
expression judgements (expression 0 judgement to expression 31 judgement) can be assigned to terminals
OUT0 to OUT2 and output to external devices.
Wiring
Example: Signals are assigned to terminals OUT0 to OUT2 as shown below.
• OUT0: Item 2 judgement (OR2)
• OUT1: Item 5 judgement (OR5)
• OUT2: Item 14 judgement (OR14)
As described above, if terminals OUT0 to OUT2 are all assigned to individual judgement output signals, the
BUSY signal and ERROR signal assigned as the default settings will no longer be output.
The timing for updating the OR signal and the ON time after judgement processing can be adjusted.
Adjusting the judgement output timing: p. 288
Output terminal
Default assignment
Output signals that can be assigned
OUT0
OR (Total judgement)
• Control signals: OR, BUSY, ERROR, READY, and RUN
STG (strobe trigger)
• Item judgements: OR0 (Item 0 judgement) to OR31
(Item 31 judgement)
• Expression judgements: Expression 0 judgement to
expression 31 judgement
OUT1
BUSY
OUT2
ERROR
The timing for updating the OR0 to OR31 signals and the ON time after judgement processing can be
changed.
Adjusting the judgement output timing: p. 288
Color
Signal
Description
The signals shown at the left are used.
Refer to the following information for signal wiring.
Black
OUT0 (OR2)
Outputs the judgement for
OR2.
Orange
OUT1 (OR5)
Outputs the judgement for
OR5.
Light
blue
OUT2 (OR14)
Outputs the judgement for
OR14.
Note
Note
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......