Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
FQ2-S4 User’s Manual
317
8
Controll
ing
Ope
rati
on a
nd Outputting
Data
wi
th
a
Para
llel
Co
nne
ctio
n
[Image]
−
[Camera setup]
−
[
]
−
[Lighting control]
1
Change the setting for lighting control.
When the strobe polarity is set to [Negative], a delay of about 200 to 300
µ
s occurs from when the TRIG signal
is input until the STGOUT signal goes low. When a high-speed shutter is used, set the [Output polarity]
parameter to [Positive].
• Timing Chart for Strobe Trigger Output Signal
The STGOUT signal turns ON in sync with the trigger input signal from an external device.
Controlling Operation from an External Device
The following Sensor functions can be controlled with command inputs from an external device without
connecting the Touch Finder.
Item
Parameter
Setting
Description
Lighting control
Strobe output delay 0 to 65,535
µ
s
(default: 0
µ
s)
Enter the delay time from when the TRIG signal is
input until the external lighting is lit.
Strobe output time
0 to 65,535
µ
s
(default: 1,000
µ
s)
Set the pulse width of the output signal (STGOUT)
that tells the external lighting when to light.
Operation
Description
Reference
Switching the scene
This command changes the scene when the line process changes.
Clearing measurement
values
This command clears the measurement values.
The OR signal and D signals are not cleared.
Clearing an error
This command turns the ERROR signal OFF.
The ERROR indicator is also turned OFF.
Re-registering the model
and reference color
This command re-registers the model and reference color.
Teaching
This command uses the image that is currently being input to execute
teaching for all of the registered items.
Clearing the OR and D sig-
nals
This command clears the OR signal and D signals.
Saving data in the Sensor
This command saves the current settings (scene data and system data)
in the Sensor.
Important
Trigger input (TRIG)
Exposure time
Imaging element
shutter signal
STGOUT
Trigger delay
Strobe output delay
Strobe output time
ON
OFF
ON
OFF
ON
OFF
Polarity of all output signals: Positive
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......