Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
FQ2-S4 User’s Manual
303
8
Controll
ing
Ope
rati
on a
nd Outputting
Data
wi
th
a
Para
llel
Co
nne
ctio
n
Performing Continuous Measurements
Continuous measurements are performed while the continuous measurement command is input from an
external device.
Setting Output Data
You can set the data to output after measurements.
Output Data
You can output any of the following data through the Parallel Interface Sensor Data Unit.
Outputting the Overall Judgement Result (OR Signal)
When the results of the inspection items are judged, if even one individual judgement result is NG, the OR
output signal is turned ON.
Data
Output contents
Signal used to output the data
OR signal
Overall judgement result
The results is output with the OR signal.
Parallel judgement
output
Judgement results of the judgement conditions
that are set for parallel output
The results are assigned to and output with
D0 to D15.
Parallel data output
Measurement values for inspection items and
results from expressions
The data is output as 16-bit data on D0 to
D15.
• You can also turn ON the overall judgement result output signal when all individual judgement results are OK.
Changing the Judgement Output ON Conditions: p. 290
• You can select whether to use the judgement result of one of the calculations (0 through 31) as the overall judge-
ment.
Using Calculation Results without Applying Them to the Overall Judgement: p. 203
• You can adjust the timing for outputting the OR signal and the ON time after judgement processing.
Adjusting the Judgement Output Timing: p. 288
PLC
(2) Performs continuous
measurements
Or other
device
(1) IN7 signal ON (IN0 to IN6 are OFF)
Note
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......