![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879195.webp)
Inspecting with the Labeling Inspection Item
FQ2-S4 User’s Manual
4
Setting Up
Inspect
ions
193
Changing the Label Extraction Conditions
Set the label extraction conditions. You can select to extract only labels that satisfy all four of the following:
Number of labels, specified area, gravity X, and gravity Y conditions.
[Inspect]
−
[Inspection]
−
[Labeling]
−
[Modify]
−
[Settings] Details
−
[Details] Tab Page
−
[Meas.
Parameter]
−
[Extraction condition]
Sorting Extracted Labels
Set the sort condition and count for extracted labels. You can set the sort condition and the maximum number
of detections for detection results.
[Inspect]
−
[Inspection]
−
[Labeling]
−
[Modify]
−
[Details] Tab Page
−
[Meas. Parameter]
1
Press and set each of the parameters for the extrac-
tion conditions.
Item
Parameter
Setting
Description
Extraction
condition
Number of
labels
Range: 1 to 100
Default: 100
Set the maximum number of labels to detect.
Area
Range: 0 to 999,999,999.9999
Defaults: Upper limit: 999,999,999.9999,
Lower limit: 0
Specify the area range to judge as a label.
Gravity X
Range:
−
99,999,999.9999 to
999,999,999.999
Defaults: Upper limit: 999,999,999.999,
Lower limit:
−
999,999,999.9999
Specify the gravity X position to judge as a label.
Gravity Y
Range:
−
999,999,999.9999 to
999,999,999.999
Defaults: Upper limit: 999,999,999.999,
Lower limit:
−
999,999,999.9999
Specify the gravity Y position to judge as a label.
1
Press [Sorting method].
2
Select the sorting method.
Item
Parameter
Setting
Description
Measure-
ment
parameter
Sorting method Area ascending order
Area descending order
Pos. X ascending order (ascending order of
X coordinate) (default)
Pos. X descending order (descending order
of X coordinate)
Pos. Y ascending order (ascending order of
Y coordinate)
Pos. Y descending order (descending order
of Y coordinate)
Set the condition to use for label number reassignment.
When sorting by X or Y coordinates, the upperleft corner
is the origin.
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......