![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879353.webp)
Outputting Data and Controlling Operation through EtherNet/IP
FQ2-S4 User’s Manual
351
Con
necting
throu
gh
Eth
e
rnet
9
• Output Area
The output area is assigned immediately after the response area in I/O memory.
Bits
Contents
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
+8
DATA 0
Output data
0 (32 bits)
+9
·
·
·
·
·
·
·
·
·
+22
DATA 7
Output data
7 (32 bits)
+23
·
·
·
·
·
·
·
·
·
+38
DATA 15
Output data
15 (32 bits)
+39
·
·
·
·
·
·
·
·
·
+70
DATA 31
Output data
31 (32 bits)
+71
·
·
·
·
·
·
·
·
·
+134
DATA 63
Output data
63 (32 bits)
+135
Signal
Signal name
Function
Application
DATA0-63
Output data 0 to 63
These I/O ports output the output data that is
specified for the data output method.
The data that can be output is determined by
the set value of the Output data size setting as
follows:
32 bytes: Output data 0 to 7
64 bytes: Output data 0 to 15
128 bytes: Output data 0 to 31
256 bytes: Output data 0 to 63
Command/
response commu-
nications
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......