![background image](http://html1.mh-extra.com/html/omron/fq2-s4/fq2-s4_user-manual_742879357.webp)
Outputting Data and Controlling Operation through EtherNet/IP
FQ2-S4 User’s Manual
355
Con
necting
throu
gh
Eth
e
rnet
9
• Response Area
• Output Area
●
Accessing Communications Areas by Specifying I/O Memory Addresses
AT specifications can be set for variables to individually specify the I/O memory addresses that are assigned in
the communications areas.
1
Setting Tag Sets (Network Configurator)
Specify the tag names in the PLC directly by using the I/O memory addresses that are assigned in the
communications areas. (Output tags are specified for the input connections to the Sensor and input tags
are specified for output connections to the PLC.)
Setting Examples
Output tag: D0
Input tag: D100
2
Setting Variables (Sysmac Studio)
Define variables with AT specifications to the I/O memory addresses that are assigned in the communi-
cations areas as shown below.
Setting Examples
Variable:
a
(AT specification: D0.0)
Variable:
b
(AT specification: D0.1)
Variable:
c
(AT specification: D0.15)
Variable:
d
(AT specification: D1.0)
3
Setting Connections
Set the connections as shown in the following table.
Signal name
Variable name
FLG
EIPInput.StatusFlag.F[0]
BUSY
EIPInput.StatusFlag.F[1]
READY
EIPInput.StatusFlag.F[2]
OR
EIPInput.StatusFlag.F[3]
RUN
EIPInput.StatusFlag.F[4]
ERR
EIPInput.StatusFlag.F[15]
GATE
EIPInput.StatusFlag.F[16]
Command code
EIPInput.CommandCodeEcho
Response code
EIPInput.ResposeCode
Response data
EIPInput.ResposeData
Signal name
Variable name
Output data 1
EIPInput.OutputData[0]
· · ·
Output data 8
EIPInput.OutputData[7]
Originator device (PLC) settings
Target device (Sensor) settings
Input tag set: D0
Output tag set: Input101
Output tag set: D100
Input tag set: Output100
Summary of Contents for FQ2-S4
Page 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Page 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Page 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Page 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Page 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Page 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Page 593: ......